Production Information
Time Warner Cable Arena is here to make your visit as easy and enjoyable as possible. Below please find general production information for the arena. If you need further information, or have questions, please contact Trista Langdon, Arena Events and Operations Manager at
tlangdon@bobcats.com.
Steel Height: 112’ from floor
Floor size: 85’W X 200”L . More space available per advance with Director of Events.
Load In: Located at Caldwell Street between 5th Street and Trade Street Up to (2) Trucks at a time. Levelers in place.
Push Distance to end stage: 100’ Pending stage location and arena configuration.
Parking: Up to 8 Trucks and 10 Buses. Total space depends upon space management.
Show Power:
- Stage Right
1 – 200 amp 120/208 volts 3-phase 5-wire
4 – 400 amp 120/208 volts 3-phase 5-wire
- Stage Left
5 – 400 amp 120/208 volts 3-phase 5-wire
3 – 200 amp 120/208 volts 3-phase 5-wire
2 – 60 amp 120/208 volts 3-phase 5-wire
- Down Stage Left Center
1 – 200 amp 120/208 volts 3-phase 5-wire
2 – 60 amp 120/208 volts 3-phase 5-wire
- Down Stage Right Center
1 – 200 amp 120/208 volts 3-phase 5-wire
2 – 60 amp 120/208 volts 3-phase 5-wire
- Down Stage Center (far end)
2 - 200 amp 120/208 volts 3-phase 5-wire
2 – 60 amp 120/208 volts 3-phase 5-wire
- Catwalk
2 – 400 amp 120/208 volt 3-phase 5-wire
- Shore Power:
Shore power available for 6 Buses.
Backstage Offices:
6 Production Offices, share same hall.
Dressing Rooms:
4 Star Dressing Rooms that share same hall access.
Labor Information
- Stage: Local 322
- Conversion/Engineering/Ushers: In House
- Catering: Full Service In House Catering Available by Levy Restaurants.